HERED ELECTRIC · INDUSTRIAL SENSOR MANUFACTURER
Industrial Proximity & Photoelectric Sensors Built for Automation
96+ industrial sensor series (1,100+ ordering codes) across inductive, photoelectric, capacitive, magnetic, ultrasonic sensors, safety light curtains, and M8/M12 accessories — engineered for OEM machinery builders and industrial distributors.
Industrial Sensor Families
Core Sensing Technologies & OEM Hubs
Featured Catalog
Popular Industrial Sensor Series
LR18 Series Inductive Proximity Sensor
E3JK Series Through-Beam Photoelectric Sensor
LX Series Color Mark Photoelectric Sensor
HCL13 Series Capacitive Liquid Level Sensor
HCN Series Cylindrical Capacitive Proximity Sensor
HMH08 Series Hall-Effect Magnetic Proximity Sensor
HMG10 Series Magnetic Proximity Sensor
Automation Field Reality
Why Machine Builders & Maintenance Teams Switch to Hered Sensors
False Triggers from Flush vs. Non-Flush Mix-Ups
Recessing a non-flush inductive sensor inside a steel bracket causes permanent self-damping, halting machine homing cycles.
Missed Aluminum & Brass Targets
Using a 4 mm steel-rated sensor on aluminum cuts effective sensing range to ~1.6 mm, causing intermittent misses under vibration.
Ingress & Thermal Drift in CNC / Welding Cells
Under-potted housings absorb cutting oil, crack at 80°C–120°C, or false-trigger next to welding cables and VFD motor drives.
10–16 Week Backorders on Major Brands
Waiting months for a backordered M12 proximity sensor or E3JK photoelectric switch stalls final machine FAT and shipment.
Engineering Selection Matrix
6 Sensing Technologies Compared — Targets, Range & Limits
| Sensing Technology | Detectable Targets | Typical Range & Output | Limitations / Not Suitable For | OEM Hub & Guide |
|---|---|---|---|---|
| Inductive Proximity | Ferrous & non-ferrous metals (steel, stainless, aluminum, brass) | 1–40 mm · NPN / PNP / 2-Wire / Analog | Cannot detect plastic, glass, wood, or liquids; apply 0.35–0.45 reduction factor for aluminum or copper. | Inductive OEM Hub → |
| Photoelectric (Optical) | Opaque, semi-transparent & glossy objects of any material | 0.1–20 m · NPN / PNP / Relay (E3JK) | Diffuse models lose range on matte-black targets; heavy dust or steam requires through-beam optics. | Photoelectric OEM Hub → |
| Capacitive Proximity | Metals, plastics, glass, wood, powders & liquids through tank walls | 2–25 mm · NPN / PNP / AC 2-Wire | Sensitive to heavy moisture buildup or condensation on the sensing face; requires sensitivity trimming. | Capacitive OEM Hub → |
| Magnetic Proximity | Permanent magnets (including through aluminum or stainless walls) | 10–70 mm · Hall-Effect / Reed NO-NC | Requires a dedicated damping magnet on the moving part; strong stray welding fields can interfere. | Magnetic OEM Hub → |
| Ultrasonic | Clear glass, transparent films, liquids, powders & irregular surfaces | 400 mm–6 m · Switching / 4–20 mA / 0–10 V | Not suitable for foam, cotton, or sound-absorbing fabrics, or environments with severe air turbulence. | Ultrasonic (HU600) → |
| Safety Light Curtains | Fingers (14 mm), hands (20 mm) & body perimeter (40 mm / multi-beam) | 0.1–20 m · Dual OSSD / Relay (SLC-14–SLC-SR) | Must match machine risk category: high-risk presses require Type 4 (PL e), never Type 2. | Safety Curtain Hub → |
Direct Part-Number Cross-Reference
How Hered Compares to Tier-1 Brands & Generic Traders
| Evaluation Dimension | Global Tier-1 (Omron / Sick / P+F / IFM) | Generic Sensor Traders | Hered Electric (Direct Factory) |
|---|---|---|---|
| Mechanical & Electrical Fit | Industry reference (M3–M30, E3Z/E3JK, M8/M12 pinouts) | Inconsistent thread tolerances & drifting switching points | 1:1 M3–M30 thread, flush/non-flush & NPN/PNP pinout drop-in fit |
| Typical Landed Unit Cost | Premium baseline (100%) | 15%–25% (high field failure under coolant/EMI) | 30%–50% of Tier-1 factory-direct pricing with 100% electrical QC |
| Lead Time on Non-Stock SKUs | 8–16 weeks (longer on analog, high-temp & custom cables) | Dependent on spot-market brokers | 3–5 business days samples / 7–15 days standard production |
| Custom Cables & OEM Marking | High MOQ and rigid catalog options | Cannot modify cable length, PUR jackets, or connectors | Custom 3 m/5 m/10 m PVC or PUR cables, M8/M12 pigtails & laser OEM logos |
| Best-Fit Buyer Profile | Sole-source automotive AVLs or proprietary IO-Link ecosystems | Non-critical hobby or one-off spot buys | Packaging & CNC OEMs, MRO replacements & automation distributors |
Where This Lands Honestly
If your automotive plant legally mandates sole-source Sick, IFM, or Pepperl+Fuchs IO-Link sensors with zero approved equivalents, stay with that Tier-1 brand. Where your machines run standard DC 3-wire NPN/PNP, 2-wire AC/DC, analog 4–20 mA, or optical safety barriers and you want 50%+ BOM savings, 24-hour part-number cross-referencing, and custom cable lengths without rigid MOQs — Hered Electric is built specifically for that role.
Transparent OEM Procurement
Pricing Variables, MOQ & Custom Cable Lead Times
| Quote Variable | Standard Catalog Baseline | Harsh-Duty / Custom OEM | Quote Impact |
|---|---|---|---|
| 1. Housing & Environment | Nickel-plated brass M8–M30, IP67, -25°C to +70°C | SS316L stainless steel, 120°C high-temp (HIT series), or PTFE weld coating | +35% to +120% for specialized metallurgy or potting |
| 2. Cable & Connector | 2 m standard PVC pre-wired cable | 3 m / 5 m / 10 m length, oil-resistant PUR drag-chain cable, or M8/M12 connector | Modest per-meter cable or connector delta |
| 3. Output & Sensing Precision | Standard 3-wire DC NPN/PNP (NO or NC) | Extended sensing range, 0–10 V / 4–20 mA analog, or safety light curtain pair | Analog & optical safety electronics carry higher BOM |
| 4. OEM Marking & Kitting | Hered standard markings & neutral cartons | Laser-etched OEM part numbers, matched M8/M12 cables + brackets, barcode bags | Laser marking free above batch MOQ; kitting quoted per set |
MOQ & Sample Validation
- Engineering Samples: 2–5 pcs per model dispatched in 3–5 business days for PLC & machine testing.
- Mixed-SKU Distributor Orders: Flexible mixed-model consolidation across all 6 sensor families.
- Custom Cable / OEM Laser: Low factory MOQ starting from 50–100 pcs per SKU.
Realistic Lead Times
- Standard M8–M30 Inductive & E3JK / E3F: 5–10 business days from stock or assembly.
- Ultrasonic, Analog & Safety Light Curtains: 10–15 business days.
- Custom PUR Cables & OEM Packaging: 15–25 business days.
Export Terms & 100% QC
- Incoterms: EXW / FOB Ningbo or Shanghai / CIF / Express Air (DHL, FedEx, UPS).
- Factory QC: 100% switching distance, output polarity, short-circuit & dielectric test.
- Engineering Support: 24-hour Tier-1 part-number cross-reference & 18-month industrial warranty.
Technical & Sourcing FAQ
Industrial Sensor Selection & Cross-Reference Questions
What is the practical difference between flush (shielded) and non-flush (unshielded) inductive sensors?
Flush (shielded) inductive sensors focus their electromagnetic field forward and can be embedded level with metal brackets without false triggering. Non-flush (unshielded) sensors offer roughly 1.5× to 2× longer sensing distance but require a metal-free clearance zone around the sensing face. Read our Flush vs. Non-Flush Guide →
How do I calculate inductive sensing distance for aluminum, copper, or stainless steel targets?
Nominal distance (Sn) is rated on mild steel (Fe360 = 1.0). Multiply Sn by typical correction factors: 0.70–0.85 for stainless steel, 0.40–0.50 for brass, 0.35–0.45 for aluminum, and 0.30–0.40 for copper — or specify an extended-range series. See our Sensing Distance Guide →
How do I choose between NPN and PNP sensor outputs for my PLC?
PNP (sourcing) switches +24 V DC to the PLC input and is standard on European and modern IEC PLC cards. NPN (sinking) pulls the signal wire to 0 V and remains common in legacy Japanese and Asian machine controls. Always match your PLC input card common rail — see our NPN vs. PNP Guide →
When must I specify a Type 4 safety light curtain instead of Type 2?
Under IEC 61496 and ISO 13849-1, Type 4 safety light curtains (up to PL e / SIL 3) continuously cross-monitor dual OSSD channels and are required for high-risk point-of-operation guarding such as hydraulic presses and robotics cells. Type 2 (up to PL c / SIL 1) is limited to lower-risk zones. Read our Type 2 vs. Type 4 Guide →
Can Hered Electric cross-reference Omron, Sick, Pepperl+Fuchs, or IFM part numbers?
Yes. Send your existing Omron (E2E/E3Z/E3JK), Sick, Pepperl+Fuchs (NBB/NBN), or IFM sensor list. Our engineering team matches thread size (M3–M30 or rectangular), flush/non-flush geometry, sensing distance, NPN/PNP NO/NC output logic, and M8/M12 connector pinout within 24 hours.
Does Hered support custom cable lengths, PUR drag-chain cables, M12 connectors, and OEM laser marking?
Yes. With in-house CNC housing machining and sensor potting lines, we supply custom 3 m / 5 m / 10 m cables, oil-resistant PUR cables, M8/M12 quick-disconnect pigtails, laser-etched OEM part numbers, and low-MOQ validation samples.
Technical Knowledge
Sensor Selection & Engineering Guides
DIRECT FACTORY RFQ
Need sensor pricing, samples, or OEM cross-reference?
Share your target material, sensing distance, NPN/PNP output, or model code. Our engineering team replies within 24 hours.