HERED ELECTRIC · YUEQING, ZHEJIANG · DIRECT SENSOR FACTORY

Industrial Sensor Manufacturer — M3 to M30 Proximity, Optical & Safety

Send the target material and mounting clearance, not just a part number. Hered Electric manufactures 96+ industrial sensor series (1,100+ ordering codes) across inductive, photoelectric, capacitive, magnetic, ultrasonic sensors, safety light curtains, and IP67 M8/M12 cables — backed by in-house CNC machining and 100% electrical testing.

96+ Series1,100+ Ordering Codes
M3–M30Flush, Non-Flush & 120°C
100% QCSn, Polarity & IP67 Tested
HERED LR30 Series M30 Inductive Proximity Sensor
Factory-Direct Series LR30 M30 Inductive Proximity Sensor

Automation Field Reality

Why Single-Spec Sensor Selection Fails on Real Machines

Run range & safety calculators →
01 / MOUNTING MISAPPLICATION

False Triggers from Flush vs. Non-Flush Mix-Ups

Recessing a non-flush inductive sensor inside a steel bracket causes permanent self-damping, halting machine homing cycles.

Hered Fix: Clear flush/non-flush series coding plus mounting clearance guides and matched brackets.
02 / NON-FERROUS MISSES

Missed Aluminum & Brass Targets

Specifying a 4 mm steel-rated sensor on aluminum cuts effective sensing range to ~1.6 mm, causing intermittent misses under vibration.

Hered Fix: Extended-range inductive series (FR08–FR30) and published material reduction factors before ordering.
03 / COOLANT, HEAT & EMI

Ingress & Thermal Drift in CNC / Welding Cells

Under-potted housings absorb cutting oil, crack at 80°C–120°C, or false-trigger next to welding cables and VFD motor drives.

Hered Fix: Full IP67 epoxy potting, 120°C high-temperature series (HIT05–HIT25), and EMI-shielded electronics.
04 / TIER-1 LEAD TIMES

10–16 Week Backorders on Major Brands

Waiting months for a backordered M12 proximity sensor or E3JK photoelectric switch stalls final machine FAT and shipment.

Hered Fix: 24-hour part-number cross-reference with mechanical & NPN/PNP drop-in equivalents shipped directly from factory stock.

Engineering Selection Matrix

6 Sensing Technologies Compared — Targets, Range & Limits

M8/M12 Cables & Brackets →
Sensing Technology Detectable Targets Typical Range & Output Limitations / Not Suitable For OEM Hub & Guide
Inductive Proximity Ferrous & non-ferrous metals (steel, stainless, aluminum, brass) 1–40 mm · NPN / PNP / 2-Wire / Analog Cannot detect plastic, glass, wood, or liquids; apply 0.35–0.45 reduction factor for aluminum or copper. Inductive OEM Hub →
Photoelectric (Optical) Opaque, semi-transparent & glossy objects of any material 0.1–40 m · NPN / PNP / Relay (E3JK) Diffuse models lose range on matte-black targets; heavy dust or steam requires through-beam optics. Photoelectric OEM Hub →
Capacitive Proximity Metals, plastics, glass, wood, powders & liquids through tank walls 2–25 mm · NPN / PNP / AC 2-Wire Cannot sense through metal tank walls; heavy condensation on face requires sensitivity trimming. Capacitive OEM Hub →
Magnetic Proximity Permanent magnets (including through aluminum or 304 stainless walls) 10–70 mm · Hall-Effect / Reed NO-NC Requires a dedicated damping magnet on the moving part; solid carbon steel plates shunt the flux. Magnetic OEM Hub →
Ultrasonic Clear glass, transparent films, liquids, powders & irregular surfaces 400 mm–6 m · Relay / Analog (HU600) Not suitable for foam, cotton, vacuum chambers, or targets inside the 0–400 mm blind zone. Ultrasonic (HU600) →
Safety Light Curtains Fingers (14 mm), hands (20 mm) & body perimeter (40 mm / multi-beam) 0.1–20 m · Dual OSSD / Relay (SLC-14–SR) Must match machine risk category: high-risk presses require Type 4 (PL e), never Type 2. Safety Curtain Hub →

Interactive Engineering Tools

Calculate Real Sensing Range & ISO 13855 Safety Distance

Need full BOM verification? →
Effective Range (Sr) 3.2 mm
Assured Operating Distance (Sa = 0.81 × Sr) 2.6 mm

Recommended HERED family: M18/M30 Extended-Range FR18/FR30 Series if required gap exceeds 2.6 mm.

Copyable RFQ Specification Clause
Inductive proximity sensor: Sn 8 mm (Fe360), Aluminum target (0.40x -> 2.6 mm assured Sa), Flush (shielded), 10-30 V DC, IP67.

Direct Part-Number Cross-Reference

How Hered Compares to Tier-1 Brands & Generic Traders

Evaluation Dimension Global Tier-1 (Omron / Sick / P+F / IFM) Generic Sensor Traders Hered Electric (Direct Factory)
Mechanical & Electrical Fit Industry reference (M3–M30, E3Z/E3JK, M8/M12 pinouts) Inconsistent thread tolerances & drifting switching points 1:1 M3–M30 thread, flush/non-flush & NPN/PNP pinout drop-in fit
Typical Landed Unit Cost Premium baseline (100%) 15%–25% (high field failure under coolant/EMI) 30%–50% of Tier-1 factory-direct pricing with 100% electrical QC
Lead Time on Non-Stock SKUs 8–16 weeks (longer on analog, high-temp & custom cables) Dependent on spot-market brokers 3–5 business days samples / 7–15 days standard production
Custom Cables & OEM Marking High MOQ and rigid catalog options Cannot modify cable length, PUR jackets, or connectors Custom 3 m/5 m/10 m PVC or PUR cables, M8/M12 pigtails & laser OEM logos
Best-Fit Buyer Profile Sole-source automotive AVLs or proprietary IO-Link ecosystems Non-critical hobby or one-off spot buys Packaging & CNC OEMs, MRO replacements & automation distributors

Industries & Applications

Where Hered Industrial Sensors Run Every Shift

Browse all 96+ series →

Packaging & Bottling Lines

Carton presence, glossy shrink-wrap counting, and clear PET bottle tracking with E3Z, E3JK, HDB background suppression, and HRF reflectors.

Photoelectric Hub →

CNC Machine Tools & Metalworking

Chuck clamping, tool-changer homing, and chip-conveyor limits under heavy coolant using IP67 LR08–LR30 and 120°C HIT high-temp barrels.

Inductive Hub →

Presses & Robotic Workcells

Point-of-operation finger/hand guarding and perimeter access interlocking with SLC-14, SLC-20, SLC-40, SLC-LR barriers, and SLC-SR safety relays.

Safety Curtain Hub →

Plastics, Grain & Bulk Silos

Non-invasive hopper fill monitoring, dry pellet detection, and liquid tank levels through plastic/glass walls via CR18/CR30, HCF, and HU600 ultrasonic.

Capacitive Hub →

Conveyors & Intralogistics

Long-span palletizer lanes, gate interlocks, and roller-zone accumulation using E3JK 40 m through-beam sets, LJ12/LJ18 barrels, and M12 cordsets.

Cables & Brackets →

Actuators & Sealed Enclosures

High-cycle piston tracking and position feedback through sealed aluminum or 304 stainless walls with HMH12/HMH18 Hall-effect and MR reed switches.

Magnetic Hub →

Quality Control & Compliance

IEC Standards, 100% Bench Verification & Shipping Documents

Quality control details →

100% Electrical & Range Bench Check

  • Every inductive, capacitive, magnetic, and optical sensor is bench-checked for nominal switching distance (Sn), hysteresis, and NPN/PNP output polarity.
  • Short-circuit, reverse-polarity, and dielectric withstand verification prior to epoxy potting cure.

Applicable Engineering Standards

  • IEC 60947-5-2: Proximity switch test targets, mounting clearances, repeatability, and EMC boundaries.
  • IEC 60529: IP65 / IP67 epoxy-sealed enclosure protection against coolant, dust, and washdown.
  • IEC 61496 & ISO 13855: Optical beam test-rod checks and safety distance sizing for SLC curtains.

Shipping & Traceability Documents

  • Lot-coded commercial invoice, packing list, and factory outgoing inspection sheet provided per batch.
  • Model-specific wiring diagrams, dimensional drawings, and CE declaration sheets available on request before PO.

Transparent OEM Procurement

Pricing Mechanism, MOQ, Lead Time & Required RFQ Fields

OEM & Custom Builds →
Quote Variable Standard Catalog Baseline Harsh-Duty / Custom OEM Quote Impact
1. Housing & Environment Nickel-plated brass M8–M30, IP67, -25°C to +70°C SS316L stainless steel, 120°C high-temp (HIT series), or PTFE weld coating +35% to +120% for specialized metallurgy or potting
2. Cable & Connector 2 m standard PVC pre-wired cable 3 m / 5 m / 10 m length, oil-resistant PUR drag-chain cable, or M8/M12 connector Modest per-meter cable or connector delta
3. Output & Sensing Precision Standard 3-wire DC NPN/PNP (NO or NC) Extended sensing range, 0–10 V / 4–20 mA analog, or safety light curtain pair Analog & optical safety electronics carry higher BOM
4. OEM Marking & Kitting Hered standard markings & neutral cartons Laser-etched OEM part numbers, matched M8/M12 cables + brackets, barcode bags Laser marking free above batch MOQ; kitting quoted per set

MOQ & Sample Validation

  • Engineering Samples: 2–5 pcs per model dispatched in 3–5 business days via DHL/FedEx.
  • Mixed-SKU Distributor Orders: Consolidate all 6 sensor families plus M8/M12 cables in one shipment.
  • Custom Cable / OEM Laser: Factory MOQ starting from 50–100 pcs per SKU.

Realistic Lead Times & Export Terms

  • Standard Stock (M8–M30, E3F/E3Z/E3JK): 5–10 business days.
  • High-Temp, Analog & Safety Curtains: 10–15 business days.
  • Incoterms: EXW / FOB Ningbo or Shanghai / CIF / Express Air · 18-month industrial warranty.

What a Sensor Quote Actually Needs

  • Target & Range: Material (steel, aluminum, plastic, liquid) and required gap (mm/m).
  • Housing & Mounting: M3–M30 or square size; flush vs. non-flush clearance.
  • Electrical & Cable: 24 V DC NPN/PNP or AC 2-wire, NO/NC, 2 m PVC/PUR or M8/M12, plus batch qty.

Order Workflow

From Part Code or Spec Sheet to Delivered Production Batch

Start Step 01 now →
STEP 01

Send Target Spec or BOM

Share your existing Omron, Sick, Pepperl+Fuchs, or IFM part codes — or send target material, thread size, distance, and PLC input type.

STEP 02

24h Engineering Match & Quote

A Hered sensor engineer verifies mechanical dimensions, flush/non-flush clearance, and pinouts, returning matched ordering codes and tiered pricing.

STEP 03

3–5 Day Sample Validation

Receive 2–5 pcs per SKU via air courier to test switching repeatability, PLC logic, and bracket fit directly on your live machine.

STEP 04

100% QC & Export Dispatch

Batch production with optional laser OEM marking and M8/M12 cable kitting, 100% electrical testing, and FOB Ningbo/Shanghai or air delivery.

Honest Qualification Boundaries

Where Hered Electric Is Not the Right Supplier

About Hered Electric →

1. Locked Sole-Source Automotive IO-Link AVLs

If an automotive Tier-1 contract legally mandates sole-source Sick, IFM, or Pepperl+Fuchs IO-Link diagnostic sensors with zero approved cross-reference equivalents, stay with that Tier-1 brand.

2. Unverified Spot-Market Lowest-Price Lots

We do not strip out epoxy potting, reverse-polarity protection, or 100% Sn bench calibration to compete with throwaway marketplace clones that fail within weeks under cutting oil.

3. Single-Piece Retail Hobby Purchases

We supply low-MOQ validation samples for OEM machinery builders and distributors, but we are not a consumer retail store for one-off 3D-printer bed-leveling orders.

4. Uncertified High-Risk Press Guarding Without Risk Review

Never select a safety light curtain on price alone. Always confirm your machine's required IEC 61496 Type (Type 2 vs. Type 4), regional third-party certificate scope, and measured brake stop time before ordering.

Technical & Sourcing FAQ

Industrial Sensor Selection & Cross-Reference Questions

Ask an Engineer
What is the practical difference between flush (shielded) and non-flush (unshielded) inductive sensors?

Flush (shielded) inductive sensors focus their electromagnetic field forward and can be embedded level with metal brackets without false triggering. Non-flush (unshielded) sensors offer roughly 1.5× to 2× longer sensing distance but require a metal-free clearance zone around the sensing face. Read our Flush vs. Non-Flush Guide →

How do I calculate inductive sensing distance for aluminum, copper, or stainless steel targets?

Nominal distance (Sn) is rated on mild steel (Fe360 = 1.0). Multiply Sn by typical correction factors: 0.70–0.85 for stainless steel, 0.40–0.50 for brass, 0.35–0.45 for aluminum, and 0.30–0.40 for copper — or use the interactive calculator above. See our Sensing Distance Guide →

How do I choose between NPN and PNP sensor outputs for my PLC?

PNP (sourcing) switches +24 V DC to the PLC input and is standard on European and modern IEC PLC cards. NPN (sinking) pulls the signal wire to 0 V and remains common in legacy Japanese and Asian machine controls. Always match your PLC input card common rail — see our NPN vs. PNP Guide →

When should I choose capacitive or ultrasonic instead of inductive or photoelectric?

Choose capacitive sensors for plastics, liquids, glass, and powders through non-metallic tank walls (Inductive vs. Capacitive Guide →), and choose ultrasonic sensors for clear glass bottles or multi-meter silo levels where dust blinds optical lenses (Ultrasonic vs. Photoelectric Guide →).

When must I specify a Type 4 safety light curtain instead of Type 2?

Under IEC 61496 and ISO 13849-1, Type 4 safety light curtains (up to PL e / SIL 3) continuously cross-monitor dual OSSD channels and are required for high-risk point-of-operation guarding such as hydraulic presses and robotics cells. Type 2 (up to PL c / SIL 1) is limited to lower-risk zones. Read our Type 2 vs. Type 4 Guide →

Can Hered Electric cross-reference Omron, Sick, Pepperl+Fuchs, or IFM part numbers?

Yes. Send your existing Omron (E2E/E3Z/E3JK), Sick, Pepperl+Fuchs (NBB/NBN), or IFM sensor list via the RFQ form below. Our engineering team matches thread size (M3–M30 or rectangular), flush/non-flush geometry, sensing distance, NPN/PNP NO/NC output logic, and M8/M12 connector pinout within 24 hours.

Direct Factory Engineering Desk

Send Your Sensor Spec or Tier-1 BOM for a 24-Hour Quote

No sales-rep handoffs. Your inquiry goes directly to our Yueqing sensor engineering desk for part-number cross-referencing, dimensional verification, sample dispatch, and factory-direct pricing.

  • Include if known: Existing part code (Omron / Sick / P+F / IFM) or target material & gap.
  • Electrical & cable: 24 V DC NPN/PNP or AC 2-wire, NO/NC, PVC/PUR length or M8/M12.
  • Direct email: [email protected] · WhatsApp: +86 180 6639 6588
Full name or engineering contact
! Please enter your name.
Format: [email protected]
! Enter a valid work email address ([email protected]).
Include NPN/PNP, cable/M12, and sample or batch quantity
! Please enter your sensor specs or part-number list.

DIRECT FACTORY QUOTE

Request a Quote from Hered Electric

Share your sensor model, sensing distance, NPN/PNP output, or OEM quantity. Our engineering team responds within 24 hours.

  • 1,152+ catalogued industrial sensor SKUs
  • Direct factory pricing & model cross-reference
  • OEM/ODM housing, cable & private-label support