Safety Light Curtain Type 2 vs Type 4: Sizing, Resolution, and ISO 13855 Distance Guide
Under IEC 61496-1 and IEC 61496-2, Type 2 safety light curtains rely on periodic self-testing and cap a machine’s safety function at ISO 13849-1 Performance Level c (PL c) and IEC 62061 SIL 1, whereas Type 4 safety light curtains use continuous dual-channel cross-monitoring to support up to PL e and SIL 3. Specifying the wrong device type violates functional safety compliance regardless of how robust the downstream safety relay or safety PLC is, while miscalculating beam resolution or ISO 13855 minimum safety distance allows an operator to reach a moving hazard before the machine comes to rest.
Sizing a safety light curtain correctly requires three sequential engineering decisions: matching IEC 61496 Type 2 or Type 4 to the machine risk assessment, selecting beam resolution and protected height for the body part at risk, and calculating the exact ISO 13855 mounting distance from the measured stopping time.
IEC 61496 Type 2 vs Type 4 Safety Light Curtains: Fault Detection and Safety Ceilings
IEC 61496-1 defines Type 2 and Type 4 electro-sensitive protective equipment (ESPE) by how each optical barrier detects internal hardware faults and prevents dangerous failures under single-fault or accumulated-fault conditions. A downstream safety PLC or Category 4 safety relay can never elevate a Type 2 light curtain above PL c or SIL 1, because the sensing subsystem sets the upper reliability ceiling for the entire safety function.
| Functional Safety Parameter | IEC 61496 Type 2 Light Curtain | IEC 61496 Type 4 Light Curtain | Governing Standard |
|---|---|---|---|
| Maximum ISO 13849-1 Performance Level | Up to PL c (Category 2) | Up to PL e (Category 4) | ISO 13849-1 |
| Maximum IEC 62061 / IEC 61508 SIL | Up to SIL 1 / SILCL 1 | Up to SIL 3 / SILCL 3 | IEC 62061 |
| Dangerous failure rate ceiling (PFHd) | 10⁻⁶ to under 10⁻⁵ per hour | 10⁻⁸ to under 10⁻⁷ per hour | IEC 62061 |
| Internal fault detection method | Periodic self-test at defined intervals | Continuous dual-channel cross-monitoring | IEC 61496-1 |
| Behavior under a single internal fault | Loss of safety function possible between tests | Safe state maintained; fault forces OSSD off | IEC 61496-1 |
| Effective aperture angle (EAA) tolerance | Wider optical cone (typically ±5 degrees) | Narrower optical cone (typically ±2.5 degrees) | IEC 61496-2 |
| Typical machine risk profile | Minor reversible injury, low exposure | Severe irreversible injury, presses, robotics | ISO 12100 |
Choose a Type 2 safety light curtain only when a documented ISO 12100 risk assessment confirms a required Performance Level of PL c or lower (SIL 1) with reversible injury potential; switch to a Type 4 safety light curtain whenever the hazard demands PL d or PL e (SIL 2 or SIL 3), including power presses, hydraulic bending machines, robotic workcells, and high-speed automated packaging lines.

Why Effective Aperture Angle (EAA) Matters Between Type 2 and Type 4
IEC 61496-2 assigns a tighter maximum Effective Aperture Angle (EAA) to Type 4 light curtains (±2.5 degrees at operating distances above 3 m) than to Type 2 units (±5 degrees). A wider beam cone makes a Type 2 barrier easier to align during commissioning, but it also increases vulnerability to optical bypass when polished stainless-steel frames, aluminum extrusions, or reflective workpieces sit near the sensing plane and bounce infrared light around an intruding hand.
For Type 4 installations, the tighter ±2.5 degree optical cone dramatically reduces reflective bypass risk and lowers optical cross-talk between adjacent machines, though mounting brackets must be rigid enough to prevent angular drift from press vibration.
How to Size Safety Light Curtain Resolution and Protected Height
Safety light curtain sizing begins with detection capability (d), which is the minimum opaque test-rod diameter guaranteed to interrupt at least one infrared beam anywhere across the protected field. Selecting a coarser beam pitch than the body part exposed to the hazard allows fingers or hands to slip undetected between beams, whereas over-specifying a 14 mm finger curtain for a 2 m perimeter walkway adds unnecessary cost and alignment sensitivity.

| Protection Zone | Minimum Detection Capability (d) | Intrusion Factor C (ISO 13855) | Typical Protected Height / Beam Layout | Typical Application |
|---|---|---|---|---|
| Finger protection (point of operation) | 14 mm | 0 mm | 120 mm to 1,240 mm | Small assembly presses, desktop crimpers, close-reach fixtures |
| Hand protection (point of operation) | 20 mm to 30 mm | 48 mm (20 mm) to 128 mm (30 mm) | 160 mm to 1,800 mm | Hydraulic presses, CNC load doors, automated insertion stations |
| Arm and body presence (area access) | 40 mm | 208 mm | 320 mm to 2,200 mm | Palletizer openings, conveyor transfer windows, cell doorways |
| Perimeter access guarding (multi-beam) | 2, 3, or 4 beams (300–500 mm spacing) | 850 mm | 500 mm to 1,200 mm beam spans | Robot cell perimeters, stretch wrappers, AGV transfer gates |
Choose 14 mm finger resolution whenever operators must work close to the die or fixture and floor space cannot accommodate extra intrusion distance; switch to 20 mm or 30 mm hand resolution for standard loading stations with moderate mounting clearance, and reserve 40 mm grids or 2- to 4-beam barriers strictly for whole-body access guarding with generous stopping distance.
Preventing Reach-Over, Reach-Under, and Reach-Around Bypass
Protected height must cover the entire access opening so an operator cannot bypass the optical field without triggering a stop. Under ISO 13855 and ISO 13857 guidelines, mount the lowest beam low enough to prevent crawling underneath (typically 300 mm or less above the floor for perimeter access, or flush with the worktable surface for benchtop presses) and extend the top beam high enough to prevent reaching over (often 1,800 mm or higher for standing access unless a fixed top guard closes the gap).
Where the light curtain sits more than 75 mm in front of a solid machine frame, side gaps can allow an operator to stand behind the sensing plane—a presence-sensing blind spot known as stepping behind. Whenever an operator can fit between the curtain and the hazard, add fixed side barrier guards, horizontal presence-sensing light curtains, or a mandatory manual restart pushbutton positioned outside the guarded zone with a full view of the hazard.
ISO 13855 Minimum Safety Distance Calculation for Safety Light Curtains
ISO 13855 mandates that a vertical safety light curtain positioned perpendicular to the direction of approach must be mounted at a minimum safety distance S from the nearest hazard point so the machine reaches a safe state before a hand or body can cross the gap. Calculating S requires three inputs: human approach speed K, total system stopping time T, and resolution-dependent intrusion depth C.

For vertical light curtains with detection capability d of 40 mm or less, ISO 13855 defines the primary minimum safety distance equation as:
S = (K × T) + C
where:
- S is the minimum safety distance in millimeters (mm) from the sensing plane to the hazard zone.
- K is the human approach speed in millimeters per second (mm/s), starting at 2000 mm/s for hand and upper-limb approach.
- T is the total system stopping time in seconds (s), equal to the sum of light curtain response time (t1), safety relay or safety PLC processing time (t2), and worst-case mechanical brake or actuator stopping time ™.
- C is the additional intrusion distance in millimeters (mm) that a hand can penetrate through the curtain before interrupting a beam, calculated as C = 8 × (d − 14) for d up to 40 mm (with C = 0 mm when d is 14 mm or less).
The 500 mm Recalculation Rule and Multi-Beam Perimeter Formula
If the initial calculation using K = 2000 mm/s yields S greater than 500 mm, ISO 13855 permits recalculating S with the body walking approach speed K = 1600 mm/s, provided the recalculated result is not less than 500 mm. If the recalculated value drops below 500 mm, clamp the final mounting distance to 500 mm rather than moving the curtain closer.
For coarse body-detection curtains with d between 41 mm and 70 mm, or for 2-, 3-, and 4-beam perimeter safety barriers, ISO 13855 sets K = 1600 mm/s and a fixed intrusion allowance C = 850 mm (representing full arm reach through wide beam spacing), giving S = (1600 × T) + 850 mm.
Worked ISO 13855 Examples: 14 mm Finger vs 20 mm Hand vs 40 mm Body
Assume a hydraulic press has a measured mechanical stopping time tm = 0.140 s (140 ms), a safety relay controller delay t2 = 0.020 s (20 ms), and a light curtain response time t1 = 0.015 s (15 ms), giving total system response time T = 0.175 s.
| Resolution d (mm) | Intrusion C = 8(d − 14) | Initial S at K = 2000 mm/s | 500 mm Rule Check | Final Minimum Safety Distance S |
|---|---|---|---|---|
| 14 mm (finger) | 0 mm | (2000 × 0.175) + 0 = 350 mm | Under 500 mm (keep 2000 mm/s) | 350 mm |
| 20 mm (hand) | 48 mm | (2000 × 0.175) + 48 = 398 mm | Under 500 mm (keep 2000 mm/s) | 398 mm |
| 30 mm (hand) | 128 mm | (2000 × 0.175) + 128 = 478 mm | Under 500 mm (keep 2000 mm/s) | 478 mm |
| 40 mm (arm/body) | 208 mm | (2000 × 0.175) + 208 = 558 mm | Over 500 mm; recalculate at 1600 mm/s: 280 + 208 = 488 mm → clamp to 500 mm | 500 mm |
| Multi-beam perimeter | 850 mm (fixed) | Not applicable (use K = 1600 mm/s) | Direct body formula: (1600 × 0.175) + 850 = 1,130 mm | 1,130 mm |
Choose a 14 mm finger-resolution curtain when reducing S from 398 mm or 500 mm down to 350 mm is required to preserve ergonomic operator reach at the workstation; switch to a 20 mm or 40 mm curtain whenever the frame already provides 400–500 mm of physical standoff and longer optical scanning range is preferred.
Matching HERED Safety Light Curtain Series and Relay Controllers to Your Machine
Once the risk assessment confirms the required IEC 61496 Type and ISO 13855 calculation sets the beam resolution and protected height, match the physical enclosure, operating range, and output interface across the HERED Safety Light Curtains portfolio. Always verify the target machine’s Type 2 or Type 4 compliance documentation and measure actual brake stopping time with a calibrated stop-time meter during commissioning.
| HERED Series | Beam Pitch / Layout | Protected Height | Operating Range | Response Time | Output & Enclosure | Best-Fit Guarding Role |
|---|---|---|---|---|---|---|
| HERED SLC-14 | 14 mm finger pitch | 120–1,240 mm | 0.1–3 m (0.1–6 m extended) | 15 ms or less | Dual NPN / Dual PNP / OSSD, IP65 | Close-reach point-of-operation finger guarding |
| HERED SLC-20 | 20 mm hand pitch | 160–1,800 mm | 0.1–5 m (0.1–10 m extended) | 15 ms or less | Dual NPN / Dual PNP / relay interface, IP65 | Standard press loading and CNC hand guarding |
| HERED SLC-40 | 40 mm arm & body pitch | 320–2,200 mm | 0.3–12 m | 20 ms or less | Dual PNP / Dual NPN / OSSD, IP65 | Wide palletizer openings and conveyor access |
| HERED SLC-M | 10 / 14 / 20 mm options | 100–960 mm | 0.1–3 m | 10 ms or less | NPN or PNP, ultra-slim aluminum, IP65 | Tight electronics assembly and benchtop fixtures |
| HERED SLC-LR | 2, 3, or 4 beams (300–500 mm) | Multi-beam perimeter | 0.5–20 m | 15 ms or less | Dual PNP / OSSD, IP65 | Long-span robotic cell perimeter guarding |
| HERED SLC-SR | DIN-rail controller | 35 mm DIN rail | Panel mounted (IP20) | Relay stage | 2 NO safety + 1 NC aux (250 V AC / 5 A) | Dual-output OSSD interface and manual/auto restart |
Choose the HERED SLC-14 or ultra-slim HERED SLC-M when tight point-of-operation ergonomics require 10–14 mm resolution and fast response (10–15 ms or less); switch to HERED SLC-20 for general hand guarding, HERED SLC-40 or HERED SLC-LR for long-range body and perimeter zones, and pair dual-channel OSSD outputs with the HERED SLC-SR safety relay controller and IP67 M12 cables from HERED Sensor Accessories.
Commissioning Checklist for Safety Light Curtain Distance and Alignment
- Measure real machine stopping time under worst-case load: Never rely on nominal catalog brake ratings when computing T; measure stopping time at maximum press speed, full tooling inertia, and warm brake pads, then re-test periodically as mechanical brakes wear.
- Verify reflective surface clearance along the entire sensing plane: Keep bare aluminum profiles, polished stainless chutes, and glossy safety glazing outside the optical cone defined by the curtain’s EAA (minimum clearance increases linearly with emitter-to-receiver span).
- Test with a certified opaque test rod at three positions: Pass a test rod matching the rated detection capability d (14 mm, 20 mm, or 40 mm) near the emitter, at midpoint, and near the receiver across the full protected height while confirming both OSSD channels drop to 0 V immediately.
- Lock out automatic restart when full-body entry is possible: Configure manual restart on the safety relay controller whenever an operator can step completely past the light curtain, and mount the reset pushbutton outside the hazard zone with an unobstructed sightline.
- Confirm environmental rating and vibration isolation: Match the enclosure rating (IP65 on standard aluminum columns) to coolant or dust exposure, and use vibration-damping brackets on high-tonnage stamping presses to preserve optical alignment.
Frequently Asked Questions
Can a Type 2 safety light curtain achieve PL d or PL e if connected to a Category 4 safety relay?
No. Under IEC 61496-1 and ISO 13849-1, a Type 2 safety light curtain relies on periodic testing rather than continuous dual-channel cross-monitoring, which caps the sensing subsystem at PL c (SIL 1). Adding a Category 4 safety relay or SIL 3 safety PLC downstream cannot raise the overall safety function above PL c; achieving PL d or PL e requires a Type 4 safety light curtain throughout the safety chain.
How does changing from 20 mm to 14 mm resolution affect minimum safety distance?
Moving from a 20 mm hand-protection curtain to a 14 mm finger-protection curtain reduces the ISO 13855 intrusion factor C from 48 mm down to 0 mm. For the same machine stopping time T, that change lets you mount the light curtain 48 mm closer to the hazard zone—often the decisive margin on compact benchtop presses and manual load fixtures.
What happens if a reflective metal guard sits too close to a safety light curtain?
A glossy metal frame or polished chute positioned inside the light curtain’s Effective Aperture Angle (EAA) can bounce infrared beams around an intruding hand or arm from the emitter to the receiver, preventing the OSSD outputs from switching off. Prevent optical bypass by increasing the lateral clearance to shiny surfaces, painting nearby brackets matte black, or choosing a Type 4 curtain with a narrower ±2.5 degree optical cone.
References
- International Electrotechnical Commission (IEC), IEC 61496-1:2020 — Safety of machinery — Electro-sensitive protective equipment — Part 1: General requirements and tests, IEC Webstore.
- International Electrotechnical Commission (IEC), IEC 61496-2:2020 — Safety of machinery — Electro-sensitive protective equipment — Part 2: Particular requirements for equipment using active opto-electronic protective devices (AOPDs), IEC Webstore.
- International Organization for Standardization (ISO), ISO 13849-1:2023 — Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design, ISO Store.
- International Organization for Standardization (ISO), ISO 13855:2010 — Safety of machinery — Positioning of safeguards with respect to the approach speeds of parts of the human body, ISO Store.
- International Electrotechnical Commission (IEC), IEC 62061:2021 — Safety of machinery — Functional safety of safety-related control systems, IEC Webstore.
- HERED Electric, Safety Light Curtains Product Catalog (SLC-14, SLC-20, SLC-40, SLC-M, SLC-LR, SLC-SR), HERED Electric.
Explore our 1,152+ catalogued inductive, photoelectric, capacitive, and magnetic proximity sensors or request factory cross-reference support.
DIRECT FACTORY RFQ
Need sensor pricing, samples, or OEM cross-reference?
Share your target material, sensing distance, NPN/PNP output, or model code. Our engineering team replies within 24 hours.