Analog Inductive Sensors IP67

LR18 Series Inductive Proximity Sensor

The HERED LR18 Series Inductive Proximity Sensor consolidates 36 factory-standard model configurations into one engineering family, covering sensing distances (5 mm ± 10%, 8 mm ± 10%), mounting styles (Flush / Non-flush), and industrial output options (Voltage output; AC 2-wire normally open (NO); AC 2-wire normally closed (NC); DC 2-wire normally open (NO); more in table). Select your exact ordering code from the model matrix below or request OEM cross-reference support.

Model Code
LR18 Series
Sensing Distance
5 mm ± 10%, 8 mm ± 10%
Output / Wiring
Voltage output; AC 2-wire normally open (NO); AC 2-wire normally closed (NC); DC 2-wire normally open (NO); more in table
Mounting
Flush / Non-flush
Protection
IP67
Material
PBT
OEM / Custom
Custom cable lengths, M8/M12 connectors & private labeling
Technical Specifications

Technical Data

Model Specifications & Parameters

The HERED LR18 Series Inductive Proximity Sensor consolidates 36 factory-standard model configurations into one engineering family, covering sensing distances (5 mm ± 10%, 8 mm ± 10%), mounting styles (Flush / Non-flush), and industrial output options (Voltage output; AC 2-wire normally open (NO); AC 2-wire normally closed (NC); DC 2-wire normally open (NO); more in table). Select your exact ordering code from the model matrix below or request OEM cross-reference support.

Series Technical Overview

Series family LR18 Series (36 models)
Sensing distance options 5 mm ± 10%, 8 mm ± 10%
Mounting styles Flush / Non-flush
Output configurations Voltage output; AC 2-wire normally open (NO); AC 2-wire normally closed (NC); DC 2-wire normally open (NO); more in table
Supply voltage 15–30 V DC / 90–250 V AC
Protection rating IP67
Sensing face / housing PBT

Available Models & Ordering Codes (36 Variants)

Ordering Code Sensing Distance Mounting Output / Wiring Connection
LR18-05A1 5 mm ± 10% Flush AC 2-wire normally open (NO) 2 m PVC cable
LR18-05A1-P 5 mm ± 10% Flush AC 2-wire normally open (NO) M8 Connector
LR18-05A2 5 mm ± 10% Flush AC 2-wire normally closed (NC) 2 m PVC cable
LR18-05A2-P 5 mm ± 10% Flush AC 2-wire normally closed (NC) M8 Connector
LR18-05D1 5 mm ± 10% Flush DC 2-wire normally open (NO) 2 m PVC cable
LR18-05D1-P 5 mm ± 10% Flush DC 2-wire normally open (NO) M8 Connector
LR18-05D2 5 mm ± 10% Flush DC 2-wire normally closed (NC) 2 m PVC cable
LR18-05D2-P 5 mm ± 10% Flush DC 2-wire normally closed (NC) M8 Connector
LR18-05N1 5 mm ± 10% Flush DC 3-wire NPN normally open (NO) 2 m PVC cable
LR18-05N1-P 5 mm ± 10% Flush DC 3-wire NPN normally open (NO) M8 Connector
LR18-05N2 5 mm ± 10% Flush DC 3-wire NPN normally closed (NC) 2 m PVC cable
LR18-05N2-P 5 mm ± 10% Flush DC 3-wire NPN normally closed (NC) M8 Connector
LR18-05P1 5 mm ± 10% Flush DC 3-wire PNP normally open (NO) 2 m PVC cable
LR18-05P1-P 5 mm ± 10% Flush DC 3-wire PNP normally open (NO) M8 Connector
LR18-05P2 5 mm ± 10% Flush DC 3-wire PNP normally closed (NC) 2 m PVC cable
LR18-05P2-P 5 mm ± 10% Flush DC 3-wire PNP normally closed (NC) M8 Connector
LR18-05U 5 mm ± 10% Flush Voltage output —
LR18-05UI 5 mm ± 10% Flush Dual output —
LR18-08A1 8 mm ± 10% Non-flush AC 2-wire normally open (NO) 2 m PVC cable
LR18-08A1-P 8 mm ± 10% Non-flush AC 2-wire normally open (NO) M8 Connector
LR18-08A2 8 mm ± 10% Non-flush AC 2-wire normally closed (NC) 2 m PVC cable
LR18-08A2-P 8 mm ± 10% Non-flush AC 2-wire normally closed (NC) M8 Connector
LR18-08D1 8 mm ± 10% Non-flush DC 2-wire normally open (NO) 2 m PVC cable
LR18-08D1-P 8 mm ± 10% Non-flush DC 2-wire normally open (NO) M8 Connector
LR18-08D2 8 mm ± 10% Non-flush DC 2-wire normally closed (NC) 2 m PVC cable
LR18-08D2-P 8 mm ± 10% Non-flush DC 2-wire normally closed (NC) M8 Connector
LR18-08N1 8 mm ± 10% Non-flush DC 3-wire NPN normally open (NO) 2 m PVC cable
LR18-08N1-P 8 mm ± 10% Non-flush DC 3-wire NPN normally open (NO) M8 Connector
LR18-08N2 8 mm ± 10% Non-flush DC 3-wire NPN normally closed (NC) 2 m PVC cable
LR18-08N2-P 8 mm ± 10% Non-flush DC 3-wire NPN normally closed (NC) M8 Connector
LR18-08P1 8 mm ± 10% Non-flush DC 3-wire PNP normally open (NO) 2 m PVC cable
LR18-08P1-P 8 mm ± 10% Non-flush DC 3-wire PNP normally open (NO) M8 Connector
LR18-08P2 8 mm ± 10% Non-flush DC 3-wire PNP normally closed (NC) 2 m PVC cable
LR18-08P2-P 8 mm ± 10% Non-flush DC 3-wire PNP normally closed (NC) M8 Connector
LR18-08U 8 mm ± 10% Non-flush Voltage output —
LR18-08UI 8 mm ± 10% Non-flush Dual output —

Ordering & OEM Engineering Support

Specify your exact ordering code, target material, mounting clearance, and PLC input type when requesting pricing, samples, or 2D/3D CAD drawings.

DIRECT FACTORY RFQ

Need sensor pricing, samples, or OEM cross-reference?

Share your target material, sensing distance, NPN/PNP output, or model code. Our engineering team replies within 24 hours.

WhatsApp: +86 180 6639 6588

DIRECT FACTORY QUOTE

Request a Quote from Hered Electric

Share your sensor model, sensing distance, NPN/PNP output, or OEM quantity. Our engineering team responds within 24 hours.

  • 1,152+ catalogued industrial sensor SKUs
  • Direct factory pricing & model cross-reference
  • OEM/ODM housing, cable & private-label support