HIMN Series Inductive Proximity Sensor
The HERED HIMN Series Inductive Proximity Sensor consolidates 30 factory-standard model configurations into one engineering family, covering sensing distances (4 mm, 8 mm, 15 mm, 8 mm ± 10%), mounting styles (Non-flush), and industrial output options (Analog current output (4–20 mA); Analog voltage output (0–5 V); Analog voltage output (0–10 V); Analog current output (0–20 mA); more in table). Select your exact ordering code from the model matrix below or request OEM cross-reference support.
- Model Code
- HIMN Series
- Sensing Distance
- 4 mm, 8 mm, 15 mm, 8 mm ± 10%
- Output / Wiring
- Analog current output (4–20 mA); Analog voltage output (0–5 V); Analog voltage output (0–10 V); Analog current output (0–20 mA); more in table
- Mounting
- Non-flush
- Protection
- IP67
- Material
- PBT
- OEM / Custom
- Custom cable lengths, M8/M12 connectors & private labeling
Technical Data
Model Specifications & Parameters
The HERED HIMN Series Inductive Proximity Sensor consolidates 30 factory-standard model configurations into one engineering family, covering sensing distances (4 mm, 8 mm, 15 mm, 8 mm ± 10%), mounting styles (Non-flush), and industrial output options (Analog current output (4–20 mA); Analog voltage output (0–5 V); Analog voltage output (0–10 V); Analog current output (0–20 mA); more in table). Select your exact ordering code from the model matrix below or request OEM cross-reference support.
Series Technical Overview
| Series family | HIMN Series (30 models) |
|---|---|
| Sensing distance options | 4 mm, 8 mm, 15 mm, 8 mm ± 10% |
| Mounting styles | Non-flush |
| Output configurations | Analog current output (4–20 mA); Analog voltage output (0–5 V); Analog voltage output (0–10 V); Analog current output (0–20 mA); more in table |
| Supply voltage | 10–30 V DC / 20–250 V AC |
| Protection rating | IP67 |
| Sensing face / housing | PBT |
Available Models & Ordering Codes (30 Variants)
| Ordering Code | Sensing Distance | Mounting | Output / Wiring | Connection |
|---|---|---|---|---|
| HIMN4-GM12-A1 | 4 mm | Non-flush | AC 2-wire normally open (NO) | 2 m PVC cable |
| HIMN4-GM12-A2 | 4 mm | Non-flush | AC 2-wire normally closed (NC) | 2 m PVC cable |
| HIMN4-GM12-D1 | 4 mm | Non-flush | DC 2-wire normally open (NO) | 2 m PVC cable |
| HIMN4-GM12-D2 | 4 mm | Non-flush | DC 2-wire normally closed (NC) | 2 m PVC cable |
| HIMN4-GM12-I | 4 mm | Non-flush | Analog current output (4–20 mA) | 2 m PVC cable |
| HIMN4-GM12-N1 | 4 mm | Non-flush | DC 3-wire / DC 4-wire NPN normally open (NO) | 2 m PVC cable |
| HIMN4-GM12-N2 | 4 mm | Non-flush | DC 3-wire / DC 4-wire NPN normally closed (NC) | 2 m PVC cable |
| HIMN4-GM12-N3 | 4 mm | Non-flush | DC 3-wire / DC 4-wire NPN NO + NC | 2 m PVC cable |
| HIMN4-GM12-P1 | 4 mm | Non-flush | DC 3-wire / DC 4-wire PNP normally open (NO) | 2 m PVC cable |
| HIMN4-GM12-P2 | 4 mm | Non-flush | DC 3-wire / DC 4-wire PNP normally closed (NC) | 2 m PVC cable |
| HIMN4-GM12-P3 | 4 mm | Non-flush | DC 3-wire / DC 4-wire PNP NO + NC | 2 m PVC cable |
| HIMN4-GM12-T | 4 mm | Non-flush | Analog voltage output (0–5 V) | 2 m PVC cable |
| HIMN4-GM12-U | 4 mm | Non-flush | Analog voltage output (0–10 V) | 2 m PVC cable |
| HIMN4-GM12-Y | 4 mm | Non-flush | Analog current output (0–20 mA) | 2 m PVC cable |
| HIMN8-GM18-A1 | 8 mm ± 10% | Non-flush | AC 2-wire normally open (NO) | 2 m PVC cable |
| HIMN8-GM18-A2 | 8 mm ± 10% | Non-flush | AC 2-wire normally closed (NC) | 2 m PVC cable |
| HIMN8-GM18-D1 | 8 mm ± 10% | Non-flush | DC 2-wire normally open (NO) | 2 m PVC cable |
| HIMN8-GM18-D2 | 8 mm ± 10% | Non-flush | DC 2-wire normally closed (NC) | 2 m PVC cable |
| HIMN8-GM18-I | 8 mm | Non-flush | Analog current output (4–20 mA) | 2 m PVC cable |
| HIMN8-GM18-N1 | 8 mm ± 10% | Non-flush | DC 3-wire / DC 4-wire NPN normally open (NO) | 2 m PVC cable |
| HIMN8-GM18-N2 | 8 mm ± 10% | Non-flush | DC 3-wire / DC 4-wire NPN normally closed (NC) | 2 m PVC cable |
| HIMN8-GM18-P1 | 8 mm ± 10% | Non-flush | DC 3-wire / DC 4-wire PNP normally open (NO) | 2 m PVC cable |
| HIMN8-GM18-P2 | 8 mm ± 10% | Non-flush | DC 3-wire / DC 4-wire PNP normally closed (NC) | 2 m PVC cable |
| HIMN8-GM18-T | 8 mm | Non-flush | Analog voltage output (0–5 V) | 2 m PVC cable |
| HIMN8-GM18-U | 8 mm | Non-flush | Analog voltage output (0–10 V) | 2 m PVC cable |
| HIMN8-GM18-Y | 8 mm | Non-flush | Analog current output (0–20 mA) | 2 m PVC cable |
| HIMN15-GM30-I | 15 mm | Non-flush | Analog current output (4–20 mA) | 2 m PVC cable |
| HIMN15-GM30-T | 15 mm | Non-flush | Analog voltage output (0–5 V) | 2 m PVC cable |
| HIMN15-GM30-U | 15 mm | Non-flush | Analog voltage output (0–10 V) | 2 m PVC cable |
| HIMN15-GM30-Y | 15 mm | Non-flush | Analog current output (0–20 mA) | 2 m PVC cable |
Ordering & OEM Engineering Support
Specify your exact ordering code, target material, mounting clearance, and PLC input type when requesting pricing, samples, or 2D/3D CAD drawings.
Related Models
More in Analog Inductive Sensors
DIRECT FACTORY RFQ
Need sensor pricing, samples, or OEM cross-reference?
Share your target material, sensing distance, NPN/PNP output, or model code. Our engineering team replies within 24 hours.