Safety Light Curtain Manufacturer & OEM Supplier
Direct OEM supplier of industrial safety light curtains (14 mm finger, 20 mm hand, 40 mm body, compact mini & multi-beam perimeter) plus DIN-rail dual-output safety relay controllers.
Featured Safety Light Curtains
HERED SLC Safety Light Curtain Series
Machine Guarding Reality
Four Point-of-Operation & Perimeter Guarding Risks Solved by Hered
Specifying Type 2 on High-Risk Presses
Using a single-channel Type 2 curtain on a hydraulic press caps safety at PL c (SIL 1), failing PL d / PL e audits.
Incorrect ISO 13855 Mounting Standoff
Coarse 40 mm beams force larger intrusion margins (C = 208 mm), pushing operators uncomfortably far from benchtop presses.
Bulky Aluminum Columns Blocking Fixture Access
Standard 35×35 mm curtains do not fit compact electronics crimpers, desktop riveters, or tight assembly cells.
Wiring Dual OSSD Outputs Into Legacy Control Panels
Many presses lack a safety PLC and need guided-contact relays with manual/auto restart selection.
SLC Series & Sizing Matrix
6 Safety Light Curtain & Controller Series — Pitch, Height & Range
| HERED Series | Beam Pitch / Resolution | Protected Height | Operating Range & Response | Catalog Link |
|---|---|---|---|---|
| SLC-14 Finger Protection | 14 mm pitch (C = 0 mm) | 120–1,240 mm | 0.1–3 m / 6 m · ≤ 15 ms · IP65 | SLC-14 Series → |
| SLC-20 Hand Protection | 20 mm pitch (C = 48 mm) | 160–1,800 mm | 0.1–5 m / 10 m · ≤ 15 ms · IP65 | SLC-20 Series → |
| SLC-40 Body & Area Grid | 40 mm pitch (C = 208 mm) | 320–2,200 mm | 0.3–12 m · ≤ 20 ms · IP65 | SLC-40 Series → |
| SLC-M Compact Mini | 10 / 14 / 20 mm options | 100–960 mm | 0.1–3 m · ≤ 10 ms · ultra-slim | SLC-M Mini → |
| SLC-LR Multi-Beam Barrier | 2, 3, or 4 beams (300–500 mm) | Perimeter beam span | 0.5–20 m · ≤ 15 ms · IP65 | SLC-LR Barrier → |
| SLC-SR Safety Relay Controller | Dual OSSD input stage | 35 mm DIN rail (IP20) | 2 NO safety + 1 NC aux · 250 V AC / 5 A | SLC-SR Relay → |
Safety Curtain Cross-Reference
How Hered SLC Series Compares to Sick deTec, Omron F3SG & Keyence GL-R
| Evaluation Dimension | Tier-1 (Sick deTec / Omron F3SG / Keyence GL-R) | Generic Traders | Hered Electric (Direct Factory) |
|---|---|---|---|
| Protected Height & Pitch Coverage | 14 / 20 / 30 / 40 mm & multi-beam | Limited standard heights only | 10 / 14 / 20 / 40 mm & 2–4 beam, 100–2,200 mm heights |
| Response Time & Output Stage | Fast OSSD dual PNP / relay | Slow scan or single output only | ≤ 10–20 ms response with Dual PNP/NPN/OSSD & SLC-SR relay |
| Landed OEM Cost | Premium baseline (100%) | Unverified optical alignment | 35%–55% of Tier-1 with 100% beam-by-beam test-rod QC |
| Custom Heights & Bracket Kitting | Rigid standard increments | No custom mounting hardware | Custom protected heights, L-brackets & M12 extension cables |
Where This Lands Honestly
Always verify your machine's required IEC 61496 Type (Type 2 vs. Type 4), third-party certification requirements (such as CE / TÜV for specific regional regulations), and measured worst-case mechanical brake stopping time before commissioning. Share your target height, pitch, and regulatory market so our engineers confirm the exact matching SLC configuration.
OEM Procurement & QC
MOQ, Lead Times & Factory Quality Verification
MOQ & Samples
- Engineering Samples: 1–2 pairs shipped in 5–7 business days with brackets & cables.
- Custom Protected Heights: Built to exact machine opening dimensions.
- OEM Private Label: Custom aluminum housing laser marking from low batch MOQ.
Factory Lead Times
- Standard SLC-14 / SLC-20 / SLC-40: 7–12 business days.
- SLC-M Mini & SLC-LR Perimeter: 10–15 business days.
- Complete Kitted Sets (Curtain + SLC-SR + Cables): 10–15 business days.
Optical QC & Export
- 100% Beam Test: Opaque test-rod verification across every beam & OSSD drop-out timing check.
- Incoterms: EXW / FOB Ningbo or Shanghai / Express Air.
- Support: 24-hour sizing & ISO 13855 distance assistance.
Engineering & Sourcing FAQ
Safety Light Curtain Sizing & Selection FAQ
What is the difference between IEC 61496 Type 2 and Type 4 safety light curtains?
Type 2 relies on periodic self-testing and caps safety at PL c (SIL 1), while Type 4 uses continuous dual-channel cross-monitoring to support up to PL e (SIL 3). Read our complete Type 2 vs. Type 4 Sizing & Distance Guide →
How do I calculate the ISO 13855 minimum safety distance?
Use S = (K × T) + C, where K = 2000 mm/s (hand approach), T is total stopping time (curtain + relay + machine brake in seconds), and C = 8 × (d − 14) for resolution d ≤ 40 mm (C = 0 mm for 14 mm finger curtains).
When do I need the SLC-SR relay controller?
Use the SLC-SR DIN-rail controller whenever your machine does not have a safety PLC and requires force-guided 2 NO safety relay contacts (up to 250 V AC / 5 A) plus selectable manual or automatic restart.
Can Hered supply custom protected heights and matching M12 extension cables?
Yes. Specify your opening height, beam pitch (14, 20, or 40 mm), scanning span, and required cable length, and we deliver matched emitter/receiver pairs, mounting brackets, and M12 cables together.
DIRECT FACTORY RFQ
Need sensor pricing, samples, or OEM cross-reference?
Share your target material, sensing distance, NPN/PNP output, or model code. Our engineering team replies within 24 hours.